Pin
Number
Pin
Name
Description (may be empty)
1 K-Line  Ignition control (EZS), air-conditioner (KLA), PTS, safety systems (Airbag, SRS, AB) and some other
3 TNA  TD engine rotation speed
4,5 GND  Ground
6 CAN-high  CAN-High (including AirBag system in W203, W209, W220, W240, R230, ะก215 after 2004y)
7 K-Line  Engine control diagnostic (ME/MSM/CDI)
8    Ignition,...
9 K-Line ABS, ASR, ESP, ETS, BAS diagnostic
11 K-Line  Gearbox and other transmission components (EGS, ETC, FTC)
12 K-Line  All activity module (AAM), Radio (RD), ICS, ...
13 K-Line  AB diagnostic - safety systems
14 CAN-Low  CAN
15 K-Line  IC, KI), TAU, LWR diagnostic
16 +12V  Power

 

 

OBD-2 protocols:

1996-2000 : ISO-9141

2000 - 2002 : ISO 9141 or KWP 2000

2003 - 2007 : KWP 2000 or CAN

after 2007 : CAN


Some OBD-II cables schemes:

OBD-2 ISO 9141-2 (14230-4, KWP2000) simple serial cable
OBD-2 J1850 PWM, J1850 VPW serial ELM327 cable
OBD-2 universal ISO 15765-4 CAN, SAE J1850 PWM, SAE J1850 VPW, ISO 9141-2, ISO 14230-4 and SAE J1939 diagnostic cable

This information should be correct, but may be not. Please, help us to improve this document!
Is this document CORRECT or INCORRECT? Your opinion will be used to establish document status (showed at the bottom).

Want to add or correct something here? Edit this page!
Pinoutsguide.com > Cars and bikes interfaces > Pinout of Mercedes OBD II diagnostic connector
Is it correct?:
unknown
no reports
Last updated 2009-10-27 23:09:33. Edit this page. Is this document correct or incorrect? What is your opinion?
[Discuss at the forum] [Back to index] [SUBMIT new pinout]
This page contain parts under Copyright © 2000-2009 by pinouts.ru team.
No any portion of this webpage may be reproduced in any form without visible direct link to this page provided. Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.